- Contact Person : Ms. Liu Cherry
- Company Name : Wuhan Zhong Yuan Hua Dian Sci.& Tech. Co., Ltd.
- Tel : 0086-27-87180701-223
- Fax : 0086-27-87180702
- Address : Hubei,Wuhan,No.6, 6 Road,Sci. & Tech. Park of HUST, East Lake Development Zone, Wuhan, Hubei, PRC.
- Country/Region : China
- Zip : 430223
ZH-5 Embedded Electric Power Fault Recorder
Detailed Product Description
ZH-5 Embedded Electric Power Fault Recorder
DESCRIPTION
ZH-5 is the first global embedded fault recorder. The functions such as human-computer interaction, waveform displaying, analysis, edit and print are all based on embedded real time operation system (ROTS) and can work without Windows system.
STRUCTURE
Items | Main technical parameter |
Input signal | It can monitor up to 96 analog signals and 256 digital signals |
Sampling index | 1When AB segment sampling rate is 10,000Hz,transient record harmonic resolution is 99 times; 2When AB segment sampling rate is 10,000Hz,transient record on-off time resolution is 0.1ms; 3under rated current and voltage, the waveform sampling precision is not over ±0.3%; 425, the relative error in effective values measuring of voltage and current is less than ±0.5; |
Timing interface | 1support various timing modes, including NTP/SNTP, IRIG-B, PPM and PPS. 2IRIG-B, PPM, PPS timing precision is ≤-1ms. 3NTP/SNTP timing precision is ≤-20ms 4Equipment self clock precision 24-hour error is ≤±1s; 5NTP/SNTP timing supports initiative request, broadcast receiving, group broadcast receiving. And this equipment supports the mutual backup and auto switch between two time servers. |
Data sampling and record mode | Transient record data adopts A-B-C segment record mode and instantaneous value sampling. Segment C can extend infinitely according to turbulence; In transient record, AB segment sampling frequency can be 10,000, 5,000 or 2,000Hz,and for segment C, the sampling frequency is 1000Hz; In continuous stable record, the sampling frequency of all segments is 1000Hz. |
Communication interface and protocol | 1Provide 4 network interfaces, which the options are 4 fiber interfaces, or 3 net with 1 fiber interface, or 2 net with 2 fiber interface; 2Support IEC 61850-8 MMS communication protocol; 3Support TCP/IP protocol and expand 103 protocol |
Anti-electromagnetism interference | 1Can endure GB/T14598.9 strict requirement level III radiate electromagnetism turbulence 2Can endure GB/T14598.10 strict requirement level radiate fast transient turbulence 3Can endure GB/T14598.13 strict requirement level III pulse group turbulence 4Can endure GB/T14598.14 strict requirement level static discharge turbulence |